Firenor AS
Information
Products
Contacts
Trademarks
Documents
Sales representatives
News
Engineering services
Fire protection & detection equipment
Firefighting equipment
Hoses, drums, packings & fittings
Inspection and testing (NDT, pressure, performance, trial trip, etc)
Project management, construction management
All product categories
1 - Ship general
10 - Specification, estimating, drawing, instruction, courses
109 - Maintenance systems, instruction material
196 - Miscellaneous consumption articles
505 - Loose firefighting apparatuses and equip., firemen's outfit
51 - Insulation, panels, bulkheads, doors, sidescuttles,skylights
All system groups
Product name
ENGINEERING
Firenor AS designs, produces, assembles, tests, installs and performs commissioning on an enormous number of high quality active firefighting systems for onshore, offshore and marine industries. Firenor gives individual attention and care to every project. For each project, Firenor's engineering team produces tailor made documents and drawings to comply with the precise requirements of the specific project.
Zoom
Loading…
Engineering
Pamphlet
pdf
FIRE HYDRANTS
HYDRANTS Generally installed in open deck areas, walkways, and escape routes, a Firenor firewater hydrants is the ultimate piece of firefighting equipment for manually extinguishing large and devastating fires. In addition to releasing water from a traditional water supply, a high quality Firenor firewater hydrant can also have a foam connection or integrated foam tank, allowing it efficiently deliver watermixed with foam. When used this way, the hydrant creates a blanket that extinguishes the fire by cutting off the oxygen supply to the fire, a tactic which is particularly effective against oil and fuel fires.
Zoom
Loading…
Hydrants with foam tank
Pamphlet
pdf
Hydrants with foam.
Pamphlet
pdf
Hydrants
Pamphlet
pdf
FIRE PROTECTION
DELUGE SYSTEMS, MULTI ZONE The Firenor multi zone deluge skid system offers exceptional fire protection for high risk areas where rapid fire spread is a potential scenario, by allowing quick discharge of water with or without foam in case of emergency. While this system is designed for high risk fire suppression, it is also excellent for cooling purposes, general area protection, and protection of high risk objects during a fire. Additionally, the design of this system can be customized to protect against pool fires by mixing foam into water at a precise flow DELUGE SYSTEMS, SINGLE ZONE The Firenor single zone deluge skid system offers exceptional fire protection for high risk areas where rapid fire spread is a potential scenario, by allowing quick discharge of water with or without foam in case of emergency. While this system is designed for high risk fire suppression, it is also excellent for cooling purposes, general area protection, and protection of high risk objects during a fire. Additionally, the design of this system can be customized to protect against pool fires by mixing foam into water at a precise flow. DIFF SYSTEMS A Deck Integrated Fire Fighting (DIFF) system is an effective fire suppression system that is normally the primary firefighting system on a helideck. The compact design of the system also allows it to be easily installed in storage areas and hangars used for aircrafts and helicopters. This versatile system can also extinguish a pool fire by mixing foam in the water at a specified flow, should the need arise. STANDALONE DIFF SYSTEMS A Deck Integrated Fire Fighting (DIFF) system is an effective fire suppression system that is normally the primary firefighting system on a helideck. The compact design of the system also allows it to be easily installed in storage areas and hangars used for aircrafts and helicopters. This versatile system can also extinguish a pool fire by mixing foam in the water at a specified flow, should the need arise. MONITON SYSTEMS A monitor system is a fast acting fire protection system used primarily to protect against rapid fire spread in high risk areas. Due to their specialized nature and compact size, monitor systems typically replace deluge systems in high risk areas or areas with limited space, though both systems can work together as well. Monitor systems may also be used for helicopter deck protection and in other large areas to increase fire protection of those areas. A monitor system is also versatile enough to be adapted to extinguish pool fires by mixing foam into the water supply at a specific flow. DAHR SYSTEMS The Firenor Dual Agent Hose Reel (DAHR) is a high quality supplemental fire extinguishing device intended for manual use against smaller fires on and in the vicinity of helicopter decks, as well as areas with high risk of hydrocarbon fires where the primary fixed firefighting system may have limited reach. The DAHR unit combines a foam solution with compatible dry chemicals to produce a mixture that is highly efficient at extinguishing fires involving flammable liquids and offers excellent re-ignition control. When this mixture is deployed, the dry powder rapidly knocks out the fire while the foam solution secures the hazard and contributes to the cooling of the fuel.
Zoom
Loading…
DAHR Systems
Pamphlet
pdf
Deluge Systems, Multi Zone
Pamphlet
pdf
DIFF System - Standard
Pamphlet
pdf
DIFF Systems - Pressure vessel
Pamphlet
pdf
DIFF Systems, Air Driven Pump
Pamphlet
pdf
DIFF Systems, Electrilcal Pump
Pamphlet
pdf
DIFF Systems
Pamphlet
pdf
Helideck Protection Solution
Pamphlet
pdf
Monitor Systems
Pamphlet
pdf
FOAM SYSTEMS
FOAM SYSTEMS Foam role is to preventing burning liquid to contact with oxygen and resulting in suppression of the combustion. The Firenor foam system is connected to the foam ring main which efficiently supplies foam to all foam consuming equipment at the installation in the same way that firewater is supplied from the firewater pumps.
Zoom
Loading…
Foam Systems
Pamphlet
pdf
HOSE REELS
HOSE REELS The Firenor firewater hose reel is a high quality quick-response piece of equipment ideal for manual fighting of small fires and for protection of personnel during evacuation. In order to ensure optimal protection of personnel, this equipment is typically used in locations like utility areas, open deck areas, living quarters and other low risk areas where personnel are likely to be present.
Zoom
Loading…
PROJECT MANAGMENT
Firenor AS designs, produces, assembles, tests, installs, and performs commissioning on an enormous variety of high quality active firefighting systems for onshore, offshore, and marine industries. Top quality project management is a vital key to the successful delivery of large catalogue of products provided by Firenor. At Firenor, we ensure that project management is performed by individuals that fully understand every aspect of the project management processes. Firenor' s project management office (PMO) defines and maintains high quality standards for project management within the organization. We focus on standardizing and following project management policies, processes, and methods. The Firenor methodology is derived from guidelines presented in "A Guide to the Project Management Body of Knowledge" (PMBOK® Guide)
Zoom
Loading…
Project Managment
Pamphlet
pdf
SPRINKLER SYSTEMS
SPRINKLER SYSTEMS A sprinkler system offers optimal fire protection in areas where there is little to no risk of rapid fire spread. Because the nozzles of a sprinkler system automatically open if the temperature increases beyond a designated threshold, sprinkler systems provide a quick response during any fire emergency. Sprinkler systems typically provide optimal coverage and protection in areas where personnel are usually present, like commercial buildings, offices, living quarters, workshops, and similar areas.
Zoom
Loading…
TESTING
Firenor AS designs, produces, assembles, tests, installs and performs commissioning on an enormous variety of high quality active firefighting systems for onshore, offshore, and marine industries. As part of our quality assurance procedures, Firenor carries out a variety of tests during production of the equipment and prior to the delivery. Some of the tests are listed below, however Firenor can adopt its test procedures to any project specification.
Zoom
Loading…
Testing
Pamphlet
pdf
Firenor AS
Mare Safety A/S
Vike Solutions ...
Polar Internati...
Oceaneering AS
Sign in
Read more
Select language:
Arabic
Bulgarian
Catalan
Chinese_Simplified
Chinese_Traditional
Czech
Danish
Dutch
English
Estonian
Persian_Farsi
Finnish
French
German
Greek
Haitian_Creole
Hebrew
Hindi
Hungarian
Indonesian
Italian
Japanese
Korean
Latvian
Lithuanian
Hmong_Daw
Norwegian
Polish
Portuguese
Romanian
Russian
Slovak
Slovenian
Spanish
Swedish
Thai
Turkish
Ukrainian
Vietnamese
0 item(s) in cart